SIVACON S8

Low-voltage POWER DISTRIBUTION BOARD : SAFE, FLEXIBLE, EFFICIENT

Customized for Maximum Demand

DESCRIPTION

The SIVACON S8 is made for maximum demands.

  • Safe down to the last detail

The SIVACON S8 low-voltage power distribution board ensures a high level of personal and plant safety. Continuous testing to IEC 61641 and VDE 0660 Part 500-2 guarantees safety in the event of an arcing fault

  • Flexible and adaptable

Thanks to its modular concept and wide variety of components, the SIVACON S8 low-voltage power distribution board can meet all individual requirements

  • Efficient throughout the entire process

The SIVACON S8 low-voltage power distribution board is easy to plan, and using the distribution board can be quickly configured using the SIMARIS software tool. The result : time savings and planning reliability throughout the entire process

 

› Products

/ › SIVACON S8

› Description

› FEATURES

› Technical DATA

› Download BROCHURE

HIGHLIGHTS

  • System status and fault prevention are made transparent
  • Increasing plant availability
  • Identity potential saving with transparent energy flows
  • Reduce energy cost

FEATURES

  • Variable busbar positions at the top up to 6.300 A
  • Variable busbar position rear up to 7.000 A (top and/or bottom)
  • Plug-in busbar system with test finger safety, cover (IP 20B) for fast and easy replacement of fuse switch disconnectors
  • Optimal connection conditions in busbar connection compartment
  • The multi-profile bar allows for the simple assembly of modular installation devices
  • Boards for reactive power compensation with design verification according to IEC 61439 reduce transmission losses
  • Overview of power distribution, thanks to a standardized labeling system for sections and feeders
  • A modern look with design elements like the side panel and optionally extendable base

› 8 Reasons For Safety

  • Design verification by verification test in accordance with IEC 61439 - 1/-2

Design-verified connection to the SIVACON 8PS busbar trunking system

  • High level of personal safety thanks to roof plate with pressure relief
  • Comprehensive certification; high degree of test coverage, certification for use on ships and offshore platforms, & earthquake upgrade
  • The patent locking system or simple or central locking keeps doors closed even in the event of an arcing fault
  • safety in the event of an arcing fault, thanks to testing in accordance with IEC 61641 and VDE 0660 Port 500-2: restriction of the effects of the arcing fault
  • An arcing fault barrier restricts the effect to one section when an arcing fault occurs
  • The insulted main busbar prevent the occurrence of arcing
  • Safe housing

› 8 Reasons For Flexibility

  • A variety of connection option via vertical section busbar: flexible layout and optional expansions
  • Supply unit and feeder:
  • Via cable or SIVACON 8PS busbar trunking system from 630 to 6,300 A
  • From the top or bottom
  • Aluminium or copper busbar trunking system
  • The section can be installed - either single- or double-fronted - together with a main busbar system or back-to-back with a separate main busbar system
  • The standardized, circumferential rows of holes in the sheet-steel profiles allow for individual expansion
  • High level of flexibility thanks to innovative modular technology
  • The functional compartments can be divided as required with add-on modules
  • Depending on requirements, different degrees of protection can be implemented with the roof plate - ventilated or non-ventilated
  • The universal door hinge allows the hinge side to be easily changed

› 8 Reasons For Flexibility

  • Economical design
  • Efficient, flexible operation
  • Reduce service time thanks to maintenance-free section connections
  • The patented ventilation slots reduce maintenance effort
  • The patented connection terminals are safe, flexible, and easy to connect - during installation and in the event of subsequent changes
  • Reliable partners
  • The SIMARIS software tool save time throughout the process - from planning to configuration all the way to plant documentation
  • The innovative, communication-capable SENTRON components are easy to integrate

TECHNICAL DATA

  • System Overview

1. Circuit Breaker

Design

2. Universal Mounting

Design

3. Fixed-mounting

Design

4. Inline design,

plug-in

5. In-Line design,

fixed-mounted

6. Reactive power

compensation

Mounting Design

 

 

Functions

 

 

Rated Values

 

Connection Position

Cubicle Width (mm)

 

Internal Separation

Busbar Position

:

 

 

:

 

 

:

 

:

:

 

:

:

  • Fixed-mounted design
  • Withdrawable

 

  • Supply
  • Outgoing
  • Coupling
  • Up to 6,300 A

 

Front / Rear

400, 600, 800,

1000, 1400

Form 1, 2b, 3a, 4b, 4 type 7 (BS)

Top / Rear

Mounting Design

 

 

Functions

 

 

Rated Values

 

Connection Position

Cubicle Width (mm)

 

Internal Separation

Busbar Position

:

 

 

:

 

 

:

 

:

:

 

:

:

  • Fixed-mounted design with compartment door
  • Plug-in
  • Cable feeders

 

 

  • Up to 630 A

 

Front / Rear

600, 1000, 1200

 

Form 3b, 4a, 4b, 4 type 7 (BS)

Top / Rear

Mounting Design

 

 

Functions

 

 

Rated Values

 

Connection Position

Cubicle Width (mm)

 

Internal Separation

Busbar Position

:

 

 

:

 

 

:

 

:

:

 

:

:

  • Fixed-mounted design with front cover
  • Plug-in
  • Cable feeders

 

 

  • Up to 630 A

 

Front

1000, 1200

 

Form 1, 2b, 3b, 4a, 4b

Top / Rear

Mounting Design

 

 

Functions

 

 

Rated Values

 

Connection Position

Cubicle Width (mm)

 

Internal Separation

Busbar Position

:

 

 

:

 

 

:

 

:

:

 

:

:

  • Plug-in

 

 

  • Cable feeders

 

 

  • Up to 630 A

 

Front

1000, 1200

 

Form 3b, 4b

Top / Rear

Mounting Design

 

 

Functions

 

 

Rated Values

 

Connection Position

Cubicle Width (mm)

 

Internal Separation

Busbar Position

:

 

 

:

 

 

:

 

:

:

 

:

:

  • Fixed-mounted design

 

 

  • Cable feeders

 

 

  • Up to 630 A

 

Front

600, 800, 1000

 

Form 1, 2b

Rear

Mounting Design

 

 

Functions

 

 

Rated Values

 

Connection Position

Cubicle Width (mm)

 

Internal Separation

Busbar Position

:

 

 

:

 

 

:

 

:

:

 

:

:

  • Fixed-mounted design

 

 

  • Central reactive power compensation

 

  • Unchoked up to 600 kvar
  • Choked up to 500 kvar

Front

800

 

Form 1, 2b

Without / Top / Rear

Low-voltage POWER DISTRIBUTION BOARD : SAFE, FLEXIBLE, EFFICIENT

Customized for Maximum Demand

SEMACOM INTEGRATED, PT

Siemens Underlicense Switchboard

PT SEMACOM INTEGRATED

Siemens Underlicense Switchboard

A member of  Golden Light Group

CONTACT

  • OFFICE & FACTORY
  • SALES OFFICE

Tel. +62 . 251 . 861 5872 - 73

Fax. +62 . 251 . 861 5874

Tel. +62 . 21 . 5316 0906 (hunting)

Fax. +62 . 21 . 5316 0907

FOLLOW US :

Y m E ! w